What was found
FUSELAGE, CREW DOOR CUT-OUT, FWD EDGE, LOWER SIDE, ROLLER GUIDE HAS GOUGE. DOT 103-09 (ATTACHED PHOTOS) REMOVED MINOR GOUGE AT FUSELAGE, CREW DOOR ROLLER GUIDE IAW A300-600 SRM 51-73-10 AND ORIGINAL THICKNESS 0.115" AND MATERIAL LOSS IS 0.008" REMAINING THICKNESS IS 0.107" FOUND WITHIN LIMITS IAW A300-600 SRM 51-73-11. APPLIED SURFACE PROTECTION AT FUSELAGE, CREW DOOR ROLLER IAW A300-600 SRM 51-75-10.