What was found
MAIN DECK FLOOR PANEL AREA, LT Z-ANGLE HAVE 2 CRACKS AT FR74 AND FR75. VERIFIED STEP 8. INSTALLED NEW Z-ANGLE LT BTW FR73 TO FR76 MAIN DECK FLOOR PANEL AREA IAW SRM 51-40-21. JOB COMPLETE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR PANEL AREA, LT Z-ANGLE HAVE 2 CRACKS AT FR74 AND FR75. VERIFIED STEP 8. INSTALLED NEW Z-ANGLE LT BTW FR73 TO FR76 MAIN DECK FLOOR PANEL AREA IAW SRM 51-40-21. JOB COMPLETE