What was found
ENG #2, INBD FAN COWL, UPPER AFT ATTACH FITTING DAMAGED. REWORKED WITH ABRASION BY HAND UPPER AFT ATTACH FITTING WITH DAMAGE AT NR 2 ENG, INBD FAN COWL, IAW SRM 51-73-10, AFTER REWORK ORIGINAL THICKNESS: .100", MATERIAL LOSS: .068", MAX ALLOWABLE DAMAGE: 0.0039", FOUND OUT OF LIMITS IAW SRM 51-73-11. INSTALLED NEW ATTACH BRACKET USING EXISTING FASTENERS, AT NR 2 ENG, INBD FAN COWL, IAW SRM 51-40-23.