What was found
MAIN DECK FLOOR STRUCTURE, FR 10, -Y1456, FITTING PICK-UP WITH CRACK.REMOVED FITTING IN MAIN DECK FLOOR STRUCTURE, FR 10, -Y1456. IAW AIRBUS A300-600 SRM 51-40-21.FABRICATED, LOCATED AND DRILL NEW FITTING PICK-UP P/N: 2024-T3 .063, BATCH: 0004410262 IAWAIRBUSA300-600 GMM 09-08, AND SRM 51-40-40.INSTALLED NEW FITTING PICK-UP ON MAIN DECK FLOOR STRUCTURE, FR 10, -Y1456 IAW A300-600 SRM 51-40-21