What was found
CREW DOOR, EXTERNAL HANDLE INNER SIDE, LOWER EDGE HAS A GOUGE. REMOVED MINOR GOUGE AT CREW DOOR, EXTERNAL HANDLE INNER SIDE, LOWER IAW SRM 51-73-10 AND ORIGINAL THICKNESS IS 0.135" AND MATERIAL LOSS IS 0.001 AND REMAINING THICKNESS IS 0.134" AND FOUND WITH IN LIMITS IAW SRM 51-73-11. APPLIED SURFACE PROTECTION AT CREW DOOR, EXTERNAL HANDLE INNER SIDE, LOWER EDGE IAW SRM 51-75-10.