What was found
STRUCTURES, AFT LOWER FUSELAGE FROM STA 1480 TO STA 1500, S-30, HAS PROTUBERANT DENT, FLL-018, ATA 53. INSTALLED FABRICATED STRINGER SECTION, NEW HAT SECTION AND REINSTALLED SPLICE AT STGR-30. IAW B757-200PF SRM 53-00-03-2R-1 REPAIR 1 AND SRM 51-40-02-0G-0.. ACCOMPLISHED REPAIR PER B757-200PF SRM 53-00-03-2R REPAIR 1 REV 124 REQUIREMENTS. REVIEWED