What was found
FUSELAGE DAMAGE FROM PACKAGE CONTAINER AT FRAME 54 STATION 3354 LEFT SIDE PAST HYD. SERVICE DOOR. VERIFY DAMAGE AND REPORT FINDINGS TO SDF LIAISON ENGINEERING PRIOR TO STARTING INITIAL CUTOUT. FOUND 24€? LONG DENT FWD AND AFT OF FRAME 54.2. WIDTH OF DENT MEASURES FROM 3€? TO 6€? MAXIMUM. DEPTH OF SKIN DENT FROM .030 TO .300 WITH A .9€? LONG CRACK AT INTERSECTION OF FRAME AND STR 42L. THERE IS MAX OF .200 DEFLECTION OF FRAME FITTING AT UPPER FWD CORNER. THE STRINGER S42L IS ALSO DEFLECTED .080 X 9€? FWD & AFT OF FRAME.