What was found
AIR TURN BACK, NR 3 STARTER CUTOUT EICAS MESSAGE IN CLIMB, CONTINUED THROUGH FLIGHT. QRH PROCEDURE FOLLOWED. R & R NR 3 ENG START VALVE IAW AMM 80-11-02/401 & OPS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIR TURN BACK, NR 3 STARTER CUTOUT EICAS MESSAGE IN CLIMB, CONTINUED THROUGH FLIGHT. QRH PROCEDURE FOLLOWED. R & R NR 3 ENG START VALVE IAW AMM 80-11-02/401 & OPS CHECKED NORMAL.