What was found
EMERGENCY DECLARED, CARGO DOOR INDICATION EICAS PERFORMED BITE TEST ON PSEU IAW FIM 32-09 FAULT TREE 803. FOUND INTERNAL PSEU DRIVER CARD 006 AND SENSOR 892 FAULTED. REPLACED DRIVER CARD 006 IAW AMM 32-09-06, OPS CHECK GOOD. CHECKED ADJUSTMENT OF S892 SENSOR GAP, FOUND TO BE 0.100 INCHES, PERFECTLY ADJUSTED. UPON OPERATION OF DOOR, NO FAULTS FOUND. THIS CLEARS DEF 2866728.