What was found
APU BAY, INTERNAL STRUCTURE RT LONGERON, BS 1885.2 CORRODED. REMOVED CORROSION ON THE RT APU LONGERON, ORIGINAL THICKNESS 0.050", MATERIAL REMOVED 0.008". INSTALLED NEW LONGERON, SERVICABLE SEAL RETAINER, SERVICABLE SUPPORT PLATES, SERVICABLE HINGE ASSY, SERVICABLE FRAME, SERVICABLE STIFFENERS, SERVICABLE GUSSET ASSEMBLIES, AND SERVICABLE CHANNEL ASSEMBLIES IAW SRM 51-40-02-OG.