What was found
E & E COMPARTMENT, FRAME 10 LT MAIN DECK FLOOR STRUCTURE HAD A BRACKET CRACKED. INSTALLED A NEW BRACKET ON FRAME 10 LT MAIN DECK FLOOR STRUCTURE IAW SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E & E COMPARTMENT, FRAME 10 LT MAIN DECK FLOOR STRUCTURE HAD A BRACKET CRACKED. INSTALLED A NEW BRACKET ON FRAME 10 LT MAIN DECK FLOOR STRUCTURE IAW SRM 51-40-21.