What was found
AFT CARGO COMP. FLOOR STRUCT. FLOOR STRINGER HAS EVIDENCE OF CORROSION AROUND MULTIPLE NUT PLATE HOLE BTW STA 1440 AND STA 1480 APPROX LBL/RBL 16.10, INSTALLED 4 EA NUTPLATES AT AFT CARGO COMP. FLOOR STRUCT. FLOOR STRINGER BTW STA 1440 AND STA 1480 LBL 16.10 IAW B757-200PF SRM 51-40-02-0G-0