What was found
MAIN DECK FLOOR AREA STA 1620-1640 LBL 62 ANGLE BAR SURFACE BULGING AND FASTENER HEAD FULL THROUGH SIGN OF CORROSION. INSTALLED NEW ANGLE BAR FASTENER RETAINER AT MAIN DECK FLOOR AREA STA 1620-1640 LBL 62 IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR AREA STA 1620-1640 LBL 62 ANGLE BAR SURFACE BULGING AND FASTENER HEAD FULL THROUGH SIGN OF CORROSION. INSTALLED NEW ANGLE BAR FASTENER RETAINER AT MAIN DECK FLOOR AREA STA 1620-1640 LBL 62 IAW SRM 51-40-02-0G-0.