What was found
MAIN CABIN COMPARTMENT FLOOR STRUCTURE, FR 80 - 82 LT BETWEEN Y1221.2 AND Y1580.5 ZEE PROFILE CRACKED. ZEE PROFILE WAS REMOVED IAW SRM 51-40-21. INSTALLED A NEW ZEE PROFILE AT MAIN CABIN COMPARTMENT FLOOR STRUCTURE, FR80/82 LH BETWEEN Y1221.2 & Y 1580.5 IAW SRM 51-40-21-001.