What was found
FOUND THE MAIN DECK CARGO RESTRAINT FLOOR ADAPTER FITTING WITH CRACK DAMAGE AT BS 1373, RBL 47.5, FLOOR PANEL 252QFF. INSTALLED FLOOR PANEL 252QFF IAW AMM 53-01-06-400-801, REV.147. REPLACED FLOOR ADAPTER FITTING I.A.W AMM 20-11-00-910-802 REV.147 AND TORQUE BOLT TO 85 IN-LB.