MDC FLOOR STRUCTURE BETWEEN STA 1200 TO 1180 AND LBL 45 SEAT TRACK WITH CORROSION IN I/B AND O/B SIDE AND HAVE FASTENER LOOSE DOT 07-110. PERFORMED EVALUATION ON THE SEAT TRACK AT LBL 45.5 BTWN STA 1200 AND 1180. FLANGE WAS FOUND TO BE WHITIN ALLOWABLE LIMITS. PER SRM 53-00-52-1A-1. REMOVED AND REPLACE FASTENER 1(EA) PER SRM 51-40-02-0G. REVIEWED.