What was found
MAIN DECK CABIN FLOOR STRUCTURE, BS 900 - 1080, LBL 45.5 - 54.9 CORRODED, REMOVED CORROSION ON MAIN DECK CABIN FLOOR STRUCTURE FROM STA. 900-1080 AND LBL 45.5 TO 54.9 L/H IAW SRM 51-10-02-0G-0. IAW AIPC 53-40-66-01, REV 138, AND DWGS 14405003, REPLACEMENT FLOOR SUPPORT COVER PLATE INSTALLED TO ACFT CONFIGURATION IAW AIPC AND DWGS.