What was found
MDC FLOOR STR, FR 34, Y0, RT CLS ADAPTER WITH CORROSION. INSTALL 1 EACH CLS ADAPTER IAW DWG B53774150 AT FR34 Y0 RT LOCATION. IAW SRM 51-40-21-001. ACCOMPLISHED PERMANENT REPAIR IAW EO-97389-REQ1 AND VT-MAE EA 300-5314-27-A4442, REV -.