What was found
AFT CARGO COMP, FR 54.2, FROM -Y700 TO Y700, CEILING SUPPORT STRUCTURE WITH CORROSION ON EACH SCREW RECEPTACLE. REMOVED CORROSION IAW A300 SRM 53-16-18-001. DEEPEST MATERIAL LOSS IS .006. ACTION OR REPAIR IS TO REMOVE AND REPLACE (FIGURE 6 ITEM 1) P/N A25576608200. INSTALLED NEW PROFILE (CEILING SUPPORT/ 1EA) AT AFT CARGO COMP, FR 54.2, FROM -Y700 TO Y700 I.A.W. A300-600 SRM 51-40-21.