What was found
FOUND FLOOR INTERCOSTAL CORROSION AT BS 1598 FROM LBL 11 TO RBL 11 IN THE ARA AFT OF BULK CARGO COMPARTMENT. FABRICATE P/N: 146T5649-4 I.A.W DWG 146T5649 SH 1 , REV-. AND ORIGINAL PART AS A SAMPLE IAW GMM-MTX CH 9.08 REV. 15.2. INSTALLED FABRICATED INTERCOSTAL IAW SRM 51-40-02-0G REV. 95 AND DWG 146T5650, SHEET 2, REV A, AND DWG 146T5650, SHEET 3, REV A.