What was found
FOUND MAIN DECK FLOOR FITTING BROKEN AT STA 2360 RBL 33. (REPLACE). .I.A.W AMM 20-51-01-912-008 REV.50 INSTALLED MAIN DECK FLOOR FITTING AT STA 2360 RBL 33 AND TORQUED THE NUT TO 85 IN-LB.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.