What was found
STRONG FUEL SMELL ON FLT DECK FROM PACK AIR SOURCE. RT. PACK WAS ON. REF 757 FIM 71-05€“00-811. OPERATED BOTH ENGINES FOR 5 MIN PER STEP 1 OF FIM. ACCOMPLISHED BLK 2 OF FIM INSPECTED PACK SYSTEM FOR CONTAMINATION REF FIM 21-00-01/301. NO CONTAMINATION FOUND. CHKED BOTH ENGINES FOR CORRECT OIL SERVICE REF 757 M/M 12-13-01/301. OIL QUANTITY CHKED OK. NO FUMES NOTED AT ENG SHUT DOWN. OK FOR CONTINUED SERVICE