What was found
MAIN CARGO DECK RT FRAME 47 SPLICE FITTING BETWEEN STRG 24 AND STRG 26 HAS (2 EA) SPOTS OF TOOLING DAMAGE ON AFT FACE ON SPLICE FITTING. ACCOMPLISHED PERMANENT REPAIR PER EO-97689-REQ1 AND EA 300-5236-27-A4484 REV.