What was found
CREW DOOR CUTOUT, UPPER FWD CORNER HAS A GOUGE. REMOVED MINOR GOUGE AT CREW DOOR CUTOUT, UPPER FWD CORNER IAW 51-10-10-101 AND ORIGINAL THIKNESS 0.265" MATERIAL LOST 0.003" REMAINING MATERIAL 0.262" FOUND WITH IN LIMITS IAW SRM 51-73-11-001. RESTORE SURFACE PROTECTION AT CREW DOOR CUTOUT, UPPER FWD CORNER IAW SRM 51-23-10 AND 51-75-10.