What was found
L1 WINDOW ARCING IN LEFT TOP CORNER INSTALLED L1 WINDSHIELD REF MM 56-11€“01-424-015 UP TO AND INCLUDING STEP 3.E.(13). FIRST TORQUE ACCOMPLISHED AT 1400L. COMPLETED SECOND AND THIRD TORQUE AT !900 AND SEALED. CONNECTED SENSORS AND WIRES TO WINDSHIELD AND TORQUED PER AMM 56-11-01-004. COMPLETED FINAL TORQUE AT 2330. PERFORMED WINDOW HEAT TEST PER AMM 30-41-00-715, TEST OK. COMPLIED WITH WINDSHIELD WIPER OPERATION TEST PER AMM 30-42-00-501.