What was found
CREW DOOR CUTOUT, HINGE BONDING WIRE BROKEN. INSTALLED TERMINAL LUG AT BONDING JUMPER CREW DOOR IAW ESPM 20-56-22-03 AND INSTALLED BONDING JUMPER IAW AMM 20-28-11/001. BONDING TESTED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CREW DOOR CUTOUT, HINGE BONDING WIRE BROKEN. INSTALLED TERMINAL LUG AT BONDING JUMPER CREW DOOR IAW ESPM 20-56-22-03 AND INSTALLED BONDING JUMPER IAW AMM 20-28-11/001. BONDING TESTED GOOD.