What was found
MAJOR REPAIR, WHILE EVALUATING APU INLET SURROUND STRUCTURE FOUND CORROSION AT AFT STRAP STA 1825 BETWEEN S-3R TO S-6R. ATA 53-80 INSTALLED 01EA REPAIR STRAP AND 01EA OUTER STRAP AT APU INLET AFT CUTOUT STA 1825.00 BTW STGR 03-06RH IN REF B757-200PF SRM 53-80-15-2R-2 REPAIR 2 DETAIL I FIG 202 SHT 2 - 3, AND SRM 51-40-02-0G-0.