MCD FR 74 - FR 75 LH FLOOR WEB IS CORRODED. LOCATED AND DRILLED L/H PLATE SUPPORT BTWN FR74 AND FR75 IAW A300-600 SRM 51-40-44. INSTALLATION OF FRAME WEB BETWEEN FR 74 AND FR 75 IAW SRM 51-40-21.