What was found
MDC RH SIDE, FLOOR SKIN BETWEEN-Y2462 AND -Y1959 FR29 WITH CORROSION. INSTALLED PROFILE T 1(EA), BRACKET TRUST AND ADAPTER CLS 2(EA) IAW SRM 51-40-21-001 AT MDC RH SIDE FLOOR, -Y2462 AND -Y1959 FR 29.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MDC RH SIDE, FLOOR SKIN BETWEEN-Y2462 AND -Y1959 FR29 WITH CORROSION. INSTALLED PROFILE T 1(EA), BRACKET TRUST AND ADAPTER CLS 2(EA) IAW SRM 51-40-21-001 AT MDC RH SIDE FLOOR, -Y2462 AND -Y1959 FR 29.