What was found
STRINGER CRACK, AFT SIDE OF BS 1960 S-17L. COMPLETED FOR PERFORMED EGAT EI F2026A53M-1619 SEQUENCE B STEP FINAL INSPECTION. VALIDATE THE LIST OF REPAIR MATERIALS WITH PO TRACEABILITY IS DOCUMENTED ON THE FAULT THAT IS ASSOCIATED. INCLUDING FASTENERS, RAW MATERIAL, AND COMPONENTS/PARTS. FINAL INSPECTION ON REPAIR AREA TO ENSURE COMPLIANCE WITH REPAIR REQUIREMENTS.