MAIN DECK FLOOR STRUCTURE, AT FR 30 BTWN -Y0 AND -Y450, CLS ADAPTER HAS CORROSION. INSTALLED NEW CLS ADAPTER AT FR 30 BTWN -Y0 AND -Y450, IAW SRM 51-40-21-001.