What was found
MAJOR REPAIR, LT WING OTBD FLAP UPPER SURFACE OF T/E WEDGE HAD TWO DENTS INBD & OUTBD. FABRICATED REPAIR PLIES TO INSTALLED AT TWO DAMAGE AREA DAMAGE AREA NR 1 LOCATED 53.5' FORM I/B-OTBD AND 8.5" FROM T/E- FWD, SIZE OF DAMAGE IS 2.75" IN DIAMETER. DAMAGE AREA #2 LOCATED 24" FROM O/B-I/B AND 5.5" FORM T/E-FWD, SIZE OF DAMAGE IS 2.5" IN DIAMETER. IAW SRM 57-53-01-2R-1 FIGURE 201, DETAIL IV, TABLE II AND SRM 51-70-17-OG-0 PARA 4A, FIGURE 10 AND PARA 3E. OK TO INSTALL.