What was found
MAIN CABIN STA.515 APROX 10" RH FROM BUTTLINE HAS A CRACKED FLOOR SUPPORT WEB. INSTALLED FABRICATED FLOOR SUPPORT IAW SRM 51-40-02-0G-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN STA.515 APROX 10" RH FROM BUTTLINE HAS A CRACKED FLOOR SUPPORT WEB. INSTALLED FABRICATED FLOOR SUPPORT IAW SRM 51-40-02-0G-0.