What was found
FOUND MAIN DECK CARGO FLOOR FITTING CRACK DAMAGE AT BS 1109 BL 0. REMOVED DAMAGE FITTING IAW SRM 51-40-02-0G REV. 96. INSTALLED NEW FITTING IAW SRM 51-40-02-0G REV. 96 AND DWG 457T4000 SH. 11 REV. B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND MAIN DECK CARGO FLOOR FITTING CRACK DAMAGE AT BS 1109 BL 0. REMOVED DAMAGE FITTING IAW SRM 51-40-02-0G REV. 96. INSTALLED NEW FITTING IAW SRM 51-40-02-0G REV. 96 AND DWG 457T4000 SH. 11 REV. B.