What was found
NO.5 FLAP TRACK AFT FAIRING, INBOARD FWD SIDE DAMAGE. I.A.W. 747-8F SRM 57-53-70-2R-1 REFER TO SRM 51-70-05-2R-1 AND SRM 51-70-05-2R-0 REV. 49 PERFORM REPAIR AS BELOW STEP:1.1 REMOVE THE DISBONDED MATERIAL AND CLEAN.1.2 MEASURE THE DAMAGE AREA ( DIA : 1", 58.5" FROM AFT EDGE, 39" FROM INBD EDGE ).1.3 BOND THE REPAIR PLIES WITH FILM ADHESIVE CURED AT 260°F FOR 130 MINUTES WITH A MINIMUM VACUUM OF 22 IN/HG. 2. CONDITION CHECK IS SATISFACTORY. REVIEW COMPLETED