MAIN DECK, AFTER REMOVAL FLOOR STRUCTURE NEXT TO FR22, FOUND CORROSION AT FLOOR BEAM FR23 BTWN Y1456 AND Y1959. 4 GIVEN OK (INSTALL) RESTORE INITIAL CONDITION AT MAIN CABIN COMPARTMENT, FLOOR STRUCTURE NEXT TO FR 22 AND FR23