What was found
DENTED SKIN, RT WING S/S DOOR FAIRING EXTERNAL SURFACE. MEASURE THE DAMAGE AREA ( DIA : 1", 13" FROM FWD EDGE, 3.3" FROM OUTBD EDGE). BOND THE REPAIR PLIES WITH FILM ADHESIVE CURED AT 260°F FOR 130 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG. IAW SRM 52-80-02-2R-4 REFER TO SRM 51-70-05-2R-1 AND SRM 51-70-00-2R-4 REV. 49.