What was found
CRACK - PNL, R/H WING T/E CAVITY LOWER PNL, WS 695. (REPAIR). 1.I.A.W. SRM 57-51-01-2R-2 REFER TO SRM 51-70-17-0G-0 REV.96 PERFORM REPAIR AS BELOW STEP:1.1 REMOVE THE CRACK MATERIALS AND CLEAN. 1.2 MEASURE THE DAMAGE AREA (L:0.5", W:0.1", AT L/E, 62" FROM INBD EDGE). 1.3 BOND THE REPAIR PLIES WITH RESIN CURED AT 200F FOR 220 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG. 2.CONDITION CHECK IS SATISFACTORY.