What was found
MAJOR REPAIR, AFT CARGO FLOOR SPLICE EXFOLIATED IN 2 PLACES STR 30L BS 1460. REMOVED CORROSION ON OTBD WEB AT AFT CARGO, IAW SRM 51-10-02-0G-0. MEASUREMENTS ARE AS FOLLOWS: L=2.50" X W=1" X D=.050" R/T=.040" O/T=.090" ALLOWED DAMAGE 20%, MAT LOSS .050", FOUND TO BE OUT OF LIMITS, IAW SRM 53-00-03-1A-1. FIG 101 DETAIL 2. AND SRM 53-60-03-0I-1. ACCOMPLISHED REPAIR PER EO-98926-REQ1 AND STE-SAA EA 757-5360-01-B0851, REV. I/R.