What was found
MAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 HAS A CRACK. INSPECTED REMOVED AND REPLACED CRACKED BRACKET ON MAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 IAW A300-600 SRM 51-40-21. {JOB COMPLETE}
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 HAS A CRACK. INSPECTED REMOVED AND REPLACED CRACKED BRACKET ON MAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 IAW A300-600 SRM 51-40-21. {JOB COMPLETE}