What was found
INSPECTION TYPE: C, FWD CARGO BAY BS 760 STR 23L VERTICAL FRAME IS DENTED. REMOVED DAMAGE FROM FRAME. FABRICATED AND INSTALLED FRAME REPAIR IAW SRM 53-00-07-2R5, DETAIL 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, FWD CARGO BAY BS 760 STR 23L VERTICAL FRAME IS DENTED. REMOVED DAMAGE FROM FRAME. FABRICATED AND INSTALLED FRAME REPAIR IAW SRM 53-00-07-2R5, DETAIL 2.