What was found
INSPECTION TYPE:C, MAIN CARGO BAY BS 1100, LBL 25 TO LBL 45 FLOORBEAM TEE CAP HAS CORROSION AROUND EVERY NUT PLATE HOLES. REMOVED CORROSION, ORIGINAL MATERIAL THICKNESS .196 LOSS OF .056 WITH .140. REMAINING IS OUT OF SRM LIMITS REPAIRS IAW EA 120254 EO B757-5310-46223-A.