What was found
INSPECTION TYPE: C, BS 1809.5 BULKHEAD FWD HORIZONTAL INNER CHORD RT 1EA FASTENER HOLE FOUND CRACKED. CHORD AT APPROX WL 257 & RBL28 AREA IS REPAIRED IAW SRM 53-80-08-2R10, FIG 201, REV 52, ORI MATL BAC1506-2466-7075T73511, CRACK LENGTH 0.5",TRIM OUT AREA 1.1"X1.375". CATEGORY B MAJOR REPAIR WITH MATL 7075-0-0090" & 7075-0-0100" REPAIR ANGLES, 7075T6-0190" FILLER,CHORD REPAIR 15.125" SUPP INSP REQ WITHIN 6000 FLI CYC IN SRM 53-80-08-2R10, FIG 202, SHT 1 & 2.