What was found
INSPECTION TYPE:2C, RT WING INBD MID FLAP T/E COVE PANEL LOWER SURFACE PUNCTURE LOCATED 48.5" FROM INBD EDGE AND 3.5" FROM T/E, 46.5" FROM INBD EDGE AND 5.6" FROM T/E. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 60.