What was found
INSPECTION TYPE:C, BULK CARGO COMPT STA 1940 TO 2060, RBL 22.5, FLOOR PANEL SUPPORT UPPER & LOWER SURFACE FOUND SEVERAL AREA CORRODED. ORG MATERIAL IS BAC1506-2261-7075T6 & THICKNESS IS 0.050", BLENDED DEPTH IS 0.035", WIDTH 1" & LENGTH 1.5" OUT OF LIMIT, DAMAGE CUT OFF LENGTH IS 100" THIS IS A MAJOR REPAIR WITH MATL BAC1506-2261-7075T6511 AS FLOOR SUPPORT REPAIR SECTION AND 7075-0-0050IN AS REPAIR ANGLES (HEAT TREAT TO T6 CONDITION AFTER FORMING), REPAIR SIZE IS 110".