What was found
INSPECTION TYPE:3C, SPLICE STRAP CRACKED IN LT WING L/E INBD END OF PANEL 526FB AT STA 906. REMOVED FABRICATED AND INSTALLED REPLACEMENT STRAP (DOUBLER) IN LT WING L/E INTERIOR AT STA 906 IAW DWG ARB3954, SRM 51-31-01, 51-33-01 , 51-21-01.