What was found
INSPECTION TYPE:3C, FLOOR PANEL 262LF HAS BROKEN INSERT AND DELAMINATION AS MARKED. REMOVED FABRICATED AND INSTALLED REPLACEMENT FLOOR PANEL 262LF IN MAIN CARGO COMPARTMENT IAW EO MD11-5320-27386-C & DWG AEA0181.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C, FLOOR PANEL 262LF HAS BROKEN INSERT AND DELAMINATION AS MARKED. REMOVED FABRICATED AND INSTALLED REPLACEMENT FLOOR PANEL 262LF IN MAIN CARGO COMPARTMENT IAW EO MD11-5320-27386-C & DWG AEA0181.