What was found
INSPECTION TYPE:4C, LONGERON 2L SPLICE FITTING CRACKED AT BS 1129. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SPLICE FITTING AT BS 1129 L2L IAW DWG ADA8413 & SRM 51-33-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4C, LONGERON 2L SPLICE FITTING CRACKED AT BS 1129. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SPLICE FITTING AT BS 1129 L2L IAW DWG ADA8413 & SRM 51-33-01.