What was found
INFLIGHT NR 1 GREEN HYD PUMP FAILED IAW EICAS-PUMP SWITCH OFF, APPR 15 MIN LATER, LOST ALL HYD (GREEN) FLUID & SHUTDOWN PUMP NR 2, EMERGENCY DECLARED. R & R BOTH PUMPS, GEAR SWING ACCOMPLISHED, NO LEAKS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INFLIGHT NR 1 GREEN HYD PUMP FAILED IAW EICAS-PUMP SWITCH OFF, APPR 15 MIN LATER, LOST ALL HYD (GREEN) FLUID & SHUTDOWN PUMP NR 2, EMERGENCY DECLARED. R & R BOTH PUMPS, GEAR SWING ACCOMPLISHED, NO LEAKS NOTED.