As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: ASE, EMERGENCY LIGHTS DO NOT STAY ON WHEN SWITCH IS PLACED IN ON POSITION. LIGHTS FLICKER FOR ONE SECOND AND GOES OFF. REMOVED POWER SUPPLY IAW 33-51-07-022-020 INSTALLED POWER SUPPLY IAW 33-51-02-862-054 OPS & FUNCTIONAL TEST CHECKED GOOD IAW 33-51-00-715-039 & 33-51-00-725-057.